# Error: "Couldn't Connect to the Server" After MCP Authorization Succeeds

> **Note:** If you finished signing in to connect the Power My Analytics MCP connector, saw "Authorization Successful!", and your AI client still shows a connection error right afterward, this article walks you through the fix. For full setup and troubleshooting, see the [Power My Analytics MCP Server Guide](https://knowledge.powermyanalytics.com/application/tools/power-my-analytics-mcp-server-guide/) and [Troubleshooting and Important Considerations for PMA MCP Server](https://knowledge.powermyanalytics.com/application/tools/troubleshooting-and-important-considerations-for-pma-mcp-server/).

## Error

"Couldn't connect to the server. Check that the URL points to a valid MCP server."

**Data source affected:** The Power My Analytics MCP connector (Claude Desktop, Claude Web, ChatGPT, or another MCP-compatible client).

**Occurs:** Right after you finish signing in for a new or reconnected MCP connection. Your AI client's Connectors panel shows the Power My Analytics entry in a "Connection issue" state, usually with only a Reconnect option available.

## Cause

Your sign-in with Power My Analytics finished and a token was issued, but the connection step that runs immediately afterward didn't complete. This is usually one of: the connection attempt timing out, your client needing a fresh registration with the PMA server, or a corporate network or proxy allowing the sign-in page through while blocking the ongoing connection that follows it.

> **Note:** Clicking **Reconnect** does not resolve this. Reconnect reuses the same registration that failed to complete; you need to remove the connector and add it again so it registers fresh.

## Solution

1. **Remove the Power My Analytics connector completely** (not just Reconnect):

    - **Claude Web:** go to Settings > Connectors (or claude.ai/customize/connectors), find Power My Analytics, and disconnect it.
    - **Claude Desktop:** remove Power My Analytics from your connector list, then restart Claude Desktop.
    - **ChatGPT:** open **Plugins** > **Personal**, select Power My Analytics (or the name you gave the app), and remove it. You'll create it again in step 2 from **Plugins** > **+** > **Create app** > **Create MCP App**; see [Connect to the PMA MCP Server from ChatGPT](https://knowledge.powermyanalytics.com/application/tools/connect-to-the-pma-mcp-server-from-chatgpt/).
    - **Other MCP clients:** remove the Power My Analytics custom connector from that client's connector or integration settings.
2. **Add the connector again from scratch** at [https://mcp.powermyanalytics.com](https://mcp.powermyanalytics.com).
3. **Complete PMA sign-in right away.** Don't leave the authorization page open partway through: the pending sign-in session is valid for about 10 minutes, so finishing without a long pause matters.
4. **Confirm the connection registered on the PMA side.** In your Hub, go to **Organizations > MCP** and check the **Connected Application** table. A new row for your client confirms the connection registered successfully. If you don't see one after a few tries, contact support using the details below.

> **Note:** These steps won't help in three specific cases: an inactive PMA subscription, a per-minute rate limit you've temporarily hit, or a manually created API token pasted in where the sign-in flow expects one. If one of those applies, restore billing, wait about a minute, or connect through the normal sign-in instead, rather than repeating remove-and-re-add.

> **Important:** If more than one person on the same network runs into this, a corporate proxy or firewall may be the cause. It can let the ordinary PMA sign-in page through while closing the longer-running connection your AI client opens right after. To test this, have one affected person repeat steps 1 through 3 on a different network (a phone hotspot works well). If it connects there, ask your IT team to allow [https://mcp.powermyanalytics.com](https://mcp.powermyanalytics.com) and permit long-lived streaming responses through the network.

## When to Contact Support

[Submit a ticket](https://knowledge.powermyanalytics.com/support/submit-a-ticket/) if:

- The Connected Application table doesn't show a new row after a few attempts.
- These steps don't clear the error.

When you reach out, include which AI client you're using (Claude Desktop, Claude Web, ChatGPT, or other), whether you're on a shared office network, and a screenshot of the error if you have one.

## Related Articles

- [Troubleshooting and Important Considerations for PMA MCP Server](https://knowledge.powermyanalytics.com/application/tools/troubleshooting-and-important-considerations-for-pma-mcp-server/)
- [Power My Analytics MCP Server Guide](https://knowledge.powermyanalytics.com/application/tools/power-my-analytics-mcp-server-guide/)
- [Connect to the PMA MCP Server from Claude Desktop](https://knowledge.powermyanalytics.com/application/tools/connect-to-the-pma-mcp-server-from-claude-desktop/)
- [Connect to the PMA MCP Server from ChatGPT](https://knowledge.powermyanalytics.com/application/tools/connect-to-the-pma-mcp-server-from-chatgpt/)
